You are here: Products Power Management Dominion PX

Raritan Intelligent PDU Dominion PX

Dominion® PX

The Raritan PX family of high quality rack power distribution units (PDUs) offers real-time remote power monitoring of current (amps), voltage, power (kVA, kW) and energy consumption (kWH) with ISO/IEC +/- 1% billing-grade accuracy.


PRODUCT OVERVIEW

With the Dominion PX:

• Emergencies can be resolved with remote serial and TCP/IP access to outlet-level switching, improving MTTR.
• Capacity planning is simplified with unit-level and outlet-level power utilization information.
• Staff can gather detailed power information to improve uptime and productivity.
• Travel costs and time can be saved with remote power cycling and monitoring.

Information provided by the Dominion PX - displayed at the strip via an LED display, and remotely through a Web browser - can be used to improve capacity planning through power consumption information for both the PDU and individual receptacle. Precise, outlet-level access and control allows users to reboot attached devices.

Whether used alone or integrated with other Raritan solutions, the intelligent Dominion PX offers secure access with 256-bit AES encryption and strong passwords. Dominion PX supports advanced authorization options including outlet-level permissions and LDAP/S, RADIUS and Active Directory®. Flexible management interfaces support HTTP, HTTPS, IPMI, SMASH-CLP, SSH, Telnet and SNMP, as well as user-configurable, outlet-level delays for power-sequencing.

Dominion PX Remote Power Management Solutions can be integrated with the following Raritan solutions:

• KVM switches: Dominion® KX II and Paragon® II
• Secure console servers: Dominion SX
• Centralized IT infrastructure management: CommandCenter® Secure Gateway

 
VAC Outlets Rack Units Amps Per Phase
16 20 30 32 50 60
120 8 1 DPXR8-15
DPCR8-15-J
DPXR8-20
DPXR8-20L
PX-5812
120 12 Zero DPXS12-20
DPXS12-20L
DPCS12-20L-J
DPCS12-30L
DPXS12-30L
DPCS12-30L-J
120 20 Zero DPCS20-20
DPXS20-20
DPXS20-20L
DPXS20-20L-J
DPXS20-30L
DPCS20-30L-J
120 20 2 DPXR20-20
DPXR20-20L
DPXR20-30L
120 24 Zero PX-5802T
3PH
120/
208
24 Zero PX-5652
3PH
120/
208
30 Zero
208 6 2 PX-5810
208 8 1 DPXR8A-20L6
DPCR8A-20L6-J
PX-5198
208 16 Zero PX-5384
208 20 Zero DPXS20A-20L6 DPCS20A-30L6
DPXS20A-30L6
DPXS20A-30L6-J
PX-5464
PX-5464T
208 20 2 DPXR20A-20L6 DPXR20A-30L6
208 24 Zero PX-5496
230 8 1 DPXR8A-16
230 12 Zero DPXS12A-16 DPXS12A-32
230 16 Zero PX-5367 PX-5397
230 20 Zero DPXS20A-16 DPXS20A-32
PX-5469T, PX-5469
230 20 2 DPXR20A-16 DPXR20A-32
230 24 Zero DPXS24A-16T

240

8 1 DPXR8A-20AU
240 12 Zero DPXS12A-20AU DPXS12A-32AUA
240 16 Zero PX-5820
PX-5820A1
PX-5820A2
240 20 Zero DPXS20A-20AU DPXS20A-32AUA, PX-5469A2T
240 24 Zero PX-5635 PX-5501
3PH 208 6 2 PX-5119
3PH
208
18 Zero PX-5902T
3PH
208
24 Zero PX-5508 PX-5520
PX-5522, PX-5523
PX-5524
PX-5525
PX-5532
PX-5534
PX-5535
3PH
230
12 2U PX-5301
3PH
230
24 Zero PX-5551
3PH
400
12 Zero PX-5314
PX-5315
PX-5616 PX-5318
PX-5318A2
3PH
400
18 Zero PX-5906T
3PH
400
24 Zero PX-5630
PX-5633
PX-5528
PX-5530

 

FEATURES & BENIFITS

Features

Benefits

Power Distribution
Power Sequencing
(User Defined)
In the event the PX is reset, the outlets will be turned on in a user-defined sequence at user-defined intervals to prevent tripping circuit breakers due to in-rush currents. (Applies only to PX models that support switching.)
Receptacle Status Retention In the event of a power outage, power is restored only to those receptacles that were on before the outage. For PX models that don't support switching, power will be restored to all outlets.
Circuit Breakers The PX uses UL 489 circuit breakers instead of fuses in 30A/32A models or higher, meeting the newest safety standard for branch circuit protection (UL60950 third edition). This eliminates the need for spare fuses and the time to replace them. Also, in many cases, a certified/licensed electrician is required to replace a fuse, whereas circuit breakers can be reset by a user.
Power Monitoring
Power Metering The PX enables users to measure power at the outlet level (RMS, apparent power), providing an accurate view of power consumption at both a server or PDU level.
Alerting In case a threshold is exceeded, or a circuit breaker trips, the PX alerts the user via e-mail, SMS (via external gateway), audio alarm, and SNMP TRAPs, providing advanced warning before major incidents occur.
Overload Alarm User-configurable current threshold provides audible and visual alarm on current overload, allowing the user to act immediately to prevent potential burnouts and interruption of services.
Environmental Monitoring The PX supports external optional but fully integrated temperature and humidity sensors, providing early warning about hotspots or changes in cooling.
Seven-Segment LED Display Shows actual current, voltage and circuit breaker status of the PDU for both the total strip and for individual receptacles.
Remote Access
IP Auto Configuration with DHCP, BOOTP Easy setup and administration.
Flexible Remote Access Options Users can access the PX through a variety of access protocols for switching (where supported), metering, data collection and monitoring:
  • Convenient HTML GUI
  • Server Management Interface (IPMI)
  • Network Management Interface (SNMP)
  • UNIX®-like console interface via serial connector or TELNET/SSH (compatible with SMASH server management)
Dynamic DNS Support Users can access the PX over a connection with a dynamically assigned IP address - which corresponds to a single DNS name.
IPMI and SMASH CLP The first and only PDU in the world that supports industry management standards: the Intelligent Platform Management Interface (IPMI) and the Distributed Management Task Force's (DMTF) Systems Management Architecture for Server Hardware (SMASH) CLP, providing a uniform way to manage both servers and the PDU.
Power Management
HTML User Interface The PX's intuitive browser-based GUI enables remote energy management.
Outlet Grouping When using PX models which support switching in a stand-alone mode over TCP/IP, users can define multiple outlets across multiple PDUs to function as a single virtual outlet. This is useful for powering down and rebooting servers with redundant power supplies.
Virtual Outlets For PX models that support switching, outlets on multiple PX units can be grouped for ease of management and administration of servers.
Integration with Multiple Raritan Solutions Simplified power control capabilities, power on/off/recycle, is available through Raritan's Dominion KXII, Dominion SX, Paragon® II, and CommandCenter® Secure Gateway 3.1.1 or higher, providing systems administrators access to power control via one­user interface.
Security
Up to 256-bit AES Encryption The PX is the first and only PDU in the industry that supports 256-bit AES encryption.
SSL Certificate Creating individual server side SSL certificates enhances the security level of PX.
Event Logging Tracks user logins, logouts, and power activities for an audit trail to support regulatory compliance.
Local and Remote Authentication and Authorization PX provides built-in support for standards-based authentication protocols, including LDAP/S, RADIUS, and Active Directory. When deployed in conjunction with other Raritan solutions, additional authentication schemes can be supported, including TACACS+, Kerberos, and SecureID.
User-Rights Per Outlet An administrator can assign permissions on an outlet level to prevent unauthorized access.
Hardware Features
Vertical and Horizontal Rack Mount Models PX units come in a choice of space-saving form factors for vertical and horizontal rack mounting. 1U and 2U units mount horizontally on standard racks. Zero U units mount vertically on rack frames.
Integration with Industry-Leading Racks Easy integration and support for up to 5 different mounting positions in industry-leading racks.
Connections Serial RJ-12 for environmental probes, RJ-45 for serial access/Power-CIM, RJ-45 Ethernet 10/100Base-T. Link status, network activity, and 10/100 status LED. Full support for full-duplex and 100Mbps operation.
Receptacle Status LED Individual LED indicator at each receptacle allow for quick and easy status checks at the rack.
Flexibility of Connections Simultaneous connection via Ethernet (TCP/IP) and serial ports for advanced applications and redundancy of connections.